CVE-2025-8286 Scanner

CVE-2025-8286 Scanner - Unauthenticated Access vulnerability in GUralp Systems FMUS Series

Short Info


Level

Critical

Single Scan

Single Scan

Can be used by

Asset Owner

Estimated Time

10 seconds

Time Interval

10 days 14 hours

Scan only one

Domain, Subdomain, IPv4

Toolbox

-

The GUralp Systems FMUS Series is a range of seismic monitoring devices widely used by geophysical institutions, research bodies, and infrastructure monitoring services. These devices are employed to capture seismic events accurately, providing real-time data for analysis in monitoring and research environments. They are integral in critical infrastructure for predicting and forecasting seismic activity and helping in disaster preparedness. Due to their critical role in capturing precise seismic data, maintaining device integrity and security is paramount for users around the world. Researchers and professionals in the field use this hardware for continuous data monitoring in various environmental conditions. Their deployment in sensitive areas makes them a crucial part of safeguarding infrastructure and human safety.

This vulnerability allows unauthenticated access to the Telnet-based command line interface on GUralp Systems FMUS Series devices. Through this access, attackers can potentially modify the device's hardware configurations, manipulate critical data, or perform a factory reset. The lack of proper authentication controls leaves these devices open to exploitation by unauthorized users. As they are integral to seismic monitoring, any unauthorized manipulation can lead to significant data inaccuracies. The access is through an open interface, without requiring any prior privilege or user authentication, making it easy to exploit. Proper mitigation strategies are crucial to securing these devices from potential threats.

The technical details of the vulnerability highlight that attackers exploit an unauthenticated Telnet interface exposed by the FMUS Series devices. This interface listens on port 4244, allowing a connection without any credential check. Once connected, the interface provides a "Welcome" message and access to the command list, which can alter device configurations. The vulnerability resides in the default configuration that does not enforce authentication or encryption to protect data transit. The issue is exacerbated by the default settings that allow such access without any deterrents, posing severe security concerns. Security layers are required to shield this critical interface from unauthorized access.

When exploited, this vulnerability can have multiple detrimental effects. An attacker could significantly disrupt seismic monitoring activities by modifying data or resetting the device to factory conditions, disrupting settings necessary for precise monitoring. Such unauthorized access might lead to data inaccuracies that can impair decisions based on seismic activity, potentially affecting disaster readiness and response. These devices' role in infrastructure monitoring means such impacts could lead to significant public safety threats. Further, exploitation could lead to loss of trust in the monitoring infrastructure's integrity, affecting ongoing and future research and financial investments.

REFERENCES

Get started to protecting your digital assets