This scanner detects the use of Honeywell Scada Configuration File Exposure in digital assets.

Short Info


Level

Low

Single Scan

Single Scan

Can be used by

Asset Owner

Estimated Time

10 seconds

Time Interval

12 days 23 hours

Scan only one

URL

Toolbox

-

Honeywell Scada systems are utilized in industrial environments for the supervision and data acquisition of various processes. These systems are primarily used by engineers and operators to monitor and control industrial equipment across sectors such as manufacturing, energy, and utilities. The software is crucial for maintaining operational efficiency, ensuring safety standards are met, and facilitating predictive maintenance strategies. Honeywell Scada's versatility makes it a preferred choice for managing complex processes, reducing downtime, and integrating with other enterprise systems. Consequently, the security of these systems is paramount, as they often interface with critical infrastructure. Unauthorized access to Honeywell Scada systems could lead to severe operational disruptions.

Config Exposure vulnerability in Honeywell Scada entails the unintended availability of configuration files to unauthorized users. These configuration files typically contain details about system architecture, network settings, and other sensitive information. Exposure of such files can occur due to improper access permissions or lack of adequate security measures in place. When a configuration file is exposed, it can be exploited by attackers to gain insights into the network environment. This type of vulnerability is serious as it can precede more severe attacks by providing the necessary information for further exploitation. Protecting configuration files is essential to ensure industrial systems remain secure.

The Config Exposure vulnerability in Honeywell Scada is characterized by an unsecured endpoint that serves configuration files. The potentially vulnerable endpoint, such as /web_caps/webCapsConfig, could be accessed without proper authorization checks. Within these files, parameters including 'DeviceSubClass' and 'IPAddress' might be exposed, giving away information about the system’s device hierarchy and network addresses. This exposure arises when HTTP GET requests succeed and return a 200 OK status, indicating that the file retrieval, intended to be secure, was completed without authentication. The presence of specific keywords within the config file can trigger the vulnerability detection mechanism. This situation requires an immediate review of access controls to ensure proper protection of sensitive data.

If exploited, the Config Exposure vulnerability in Honeywell Scada could allow malicious actors to glean critical information about the system's network setup. This information could facilitate the planning of network-based attacks targeting the SCADA system, potentially leading to unauthorized control of industrial devices or disruption of operations. An attacker could leverage exposed IP addresses to conduct further reconnaissance or launch denial of service attacks. Moreover, the exposure of configuration settings could aid in crafting targeted malware to compromise the integrity of the system. Therefore, guarding against this vulnerability is pivotal to ensuring the confidentiality, integrity, and availability of the industrial control systems.

REFERENCES

Get started to protecting your Free Full Security Scan